Building Cavities Not Used as Supply or Return Ducts Description Guide describing the use of building cavities as supply or return ducts.
Ducts Buried in Attic Insulation and Encapsulated Description Guide describing approaches to burying and encapsulating ducts in unconditioned attics to increase the overall R-value of duct insulation.
Outdoor Air Intake Damper Controlled Description No outdoor air intakes connected to return side of the HVAC system, unless controls are installed to operate intermittently & automatically based on a timer and to restrict intake when not in use (e.g., motorized damper)
Whole-House Dehumidification Description Guide describing options for adding dehumidification equipment to a home to maintain indoor relative humidity below 60%.
Whole-House Ventilation Strategies for New Homes Description This guide describes how to install a whole-building ventilation system to provide adequate dilution of indoor air contaminants.