An official website of the United States government
Here's how you know
Official websites use .gov
A .gov website belongs to an official government organization in the United States.
Secure .gov websites use HTTPS
A lock (
) or https:// means you’ve safely connected to the .gov website. Share sensitive information only on official, secure websites.
Report analyzing design heating load sizing methods for superinsulated homes in cold climates and comparing them to the actual energy usage to determine if the building load calculation methodology should be changed for calculating the design heating load of these homes.
Report outlining the issues with using existing ducts with a new low-load HVAC system, which reduces throw at supply registers causing decreased mixing of supply and room air, leading to potential thermal comfort complaints.
Report on a project conducted to better understand the current usage of thermostatic radiator valves by key market players in steam and hot water heating and to conduct limited experiments on the effectiveness of new and old thermostatic radiator valves as a means of controlling space temperatures...
Case study describing a DOE Building America 2014 Top Innovation on research that was instrumental in developing and gaining adoption of the ASHRAE 62.2 ventilation standard.
Report describing strategies to improve the aging steam heating systems in New York City to improve energy efficiency, reduce oil and gas usage, and cut maintenance costs.
Code establishing the rules of safety relating only to pressure integrity for the design, fabrication, and inspection of boilers and pressure vessels during construction which was published in the year 2021 and is available to order at the referenced link.
Code establishing the rules of safety relating only to pressure integrity for the design, fabrication, and inspection of boilers and pressure vessels during construction which was published in the year 2017 and is available to order at the referenced link.
Standard covering equipment sizing loads for single-family-detached homes, small multi-unit structures, condominiums, town houses and manufactured homes.
Article discussing the risks that can occur from undercutting bedroom doors to provide return airflow from bedrooms, as well as corrective measures that can be taken to address these risks.
Guide describing how to undercut the doors in bedroom walls to balance air pressures between rooms and to enable stale air to return to a central heating system.
Guide describing how to install jump ducts in bedroom walls to balance air pressures between rooms, enabling stale air to return of the central air handler, even when room doors are closed.
Guide describing how to install transfer grilles in bedroom walls to balance air pressures between rooms and to enable stale air to return to a central heating system.
Information guide describing how to balance air pressure in supply and return ducts of a central forced air system to minimize drafts and help provide consistent temperatures from room to room.