Technical report describing research aimed to provide window manufacturers with foundational guidance for installing windows in walls with continuous insulation (CI), addressing critical aspects such as evaluating common installation methods, establishing acceptance criteria for window performance...
Research study searching for combinations of existing technologies that could enable a minimally invasive, cost-competitive, easily deployable method of upgrading soil-side foundation insulation in existing buildings.
This report outlines research activities that are expected to facilitate the adoption of energy retrofits by remodeling contractors and roofing contractors using retrofit panels which applicable to many existing house designs in most climates and markets.
Document providing descriptions of the many insulation options available to homeowners, along with guidance on where, when, and how to install insulation throughout your house.
Case study describing novel technique for installing exterior spray foam on foundation walls that uses high-pressure water sprayer and a “hydro vac” to remove dirt along the foundation wall.
Research report that validates Pinhole Insulation®, offering a cost-effective, minimally invasive solution for enhancing insulation and air sealing in enclosed roof cavities, improving R-value by 60% compared to traditional methods.
Document providing renovators and retrofit contractors an overview of considerations when including wall air sealing and insulation in an energy retrofit project.
Report exploring alternative methods to find long-term solutions to energy loss in 1 ½-story homes to save energy, improve comfort, prevent frost buildup on the underside of the roof deck, and reduce the risk of ice dam formation/reformation.
The Guide addresses walls constructed with 2x4 wood frame studs, wood structural panel sheathing (WSP) as wall bracing and added backing for foam sheathing, a layer of rigid foam sheathing insulation up to 1.5 inches thick over the WSP, and a cladding system installed over the foam sheathing in low...
Research study describing an experimental and theoretical investigation of the energy and hygrothermal performance of retrofit foundation insulation systems in climate zones 6 and 7.
Case study showing project and performance data and energy-efficiency measures for a DOE 2017 Housing Innovation Award winning home that was certified to the DOE Zero Energy Ready Home criteria.
Case study poster describing a DOE Zero Energy Ready Home 2022 Housing Innovation Award winning production home in the mixed-dry climate that used 2x6 16-in. o.c. walls with 5.5 inches of spray foam plus R-5 rigid continuous insulation, R-33 open-cell spray foam attic insulation, and 6.23 kW rooftop...
Case study describing a 4,763 ft2 certified Passive House that achieved HERS 27 without PV through the construction of R-54 walls that use ICF plus fiberglass cavity insulation, an R-100 vented attic, extensive air sealing and flashing, triple-pane windows, ductless heat pumps, and solar hot water.
Presentation describing the challenges of insulating an existing basement, presented to the Building America residential energy-efficiency stakeholder meeting.
Document developed to help residential new construction builders transition from using a three-coat stucco system to a one-coat stucco system installed over 1 in. of expanded polystyrene (EPS) insulation.
Case study poster describing a DOE Zero Energy Ready Home 2020 Housing Innovation Award winning production home in the mixed-humid climate that used 2x6, 24-inch on-center blown fiberglass wall insulation, OSB roof sheathing, and R-49 blown fiberglass attic insulation to achieve a HERS score of 50...
Case study poster describing a DOE Zero Energy Ready Home 2022 Housing Innovation Award winning custom spec home in the cold climate that used R-22 ICF walls, an ICF insulated basement, and an R-50 cellulose attic insulation to achieve a HERS score of 49 without PV.
Case study poster describing a DOE Zero Energy Ready Home 2022 Housing Innovation Award winning attached home in the mixed-humid climate that used 2x6 16-inch on-center walls, an R-49 insulated attic, and an insulated conditioned basement to achieve a HERS score of 45 without PV.
Case study poster describing a DOE Zero Energy Ready Home 2022 Housing Innovation Award winning production home in the mixed-humid climate that used 2x6 24-in. o.c. walls, an R-49 insulated attic, and an unvented insulated crawl space to achieve a HERS score of 46 without PV.
Case study describing a DOE Zero Energy Ready Home 2013 Housing Innovation Award Winner in Frederick MD that scored HERS 43 without PV and HERS 28 with PV.
Case study describing a DOE Zero Energy Ready Home 2013 Housing Innovation Award Winner in Phoenix, AZ that scored HERS 58 without PV and HERS 38 with PV.
Case study describing a DOE Zero Energy Ready Home 2013 Housing Innovation Award Winner in Ellenton FL that scored HERS 53 without PV and HERS 23 with PV.
Case study describing a DOE Zero Energy Ready Home 2014 Housing Innovation Award winner in the marine climate that scored HERS 43 without PV and 13 with PV.
Case study poster describing a DOE Zero Energy Ready Home 2020 Housing Innovation Award winning production home in the cold climate that used 2x6, 24-inch on-center walls, R-60 roof insulation, and R-60 blown-in fiberglass attic insulation to achieve a HERS score of 47 without PV.
Case study poster describing a DOE Zero Energy Ready Home 2020 Housing Innovation Award winning production home in the mixed-humid climate that used 2x6, 24-inch on-center walls, R-49 roof insulation, and R-49 blown-in cellulose attic insulation to achieve a HERS score of 9 with PV and 46 without PV...
Case study poster describing a DOE Zero Energy Ready Home 2020 Housing Innovation Award winning custom for buyer homes in the cold climate that used R-44 insulation in the double walls, R-60 blown fiberglass attic insulation, and triple-pane windows to achieve a HERS score of 14 with PV and 44...
Case study describing a DOE Zero Energy Ready Home 2013 Housing Innovation Award winning custom home in Devens MA that scored HERS 34 without PV or HERS -21 with PV.
Case study describing a DOE Zero Energy Ready Home 2013 Housing Innovation Award Winning production home in Devens MA that scored HERS 35 without PV or HERS -37 with PV.
Fact sheet describing the Extended Plate Wall (EPW) a system that incorporates a 2-inch layer of foam plastic insulative sheathing within the framing for top and bottom plates, streamlining air sealing, window and door installation, weather resistive barrier application, and cladding attachment for...
Case study describing a DOE Zero Energy Ready Home 2020 Housing Innovation Award winning affordable home in the cold climate that used above-grade walls filled with 5.5 inches of open-cell spray foam and sheathed with an R-6.5 insulated coated OSB sheathing, providing a continuous air barrier and...
Case study describing a DOE Zero Energy Ready Home 2013 Housing Innovation Award winning custom home in Downers Grove IL that scored HERS 35 without PV.
Case study poster describing a DOE Zero Energy Ready Home 2020 Housing Innovation Award winning affordable home in the hot-humid climate that used 2x6, 24-inch on-center walls with 5.5-inch open-cell spray foam insulation and OSB sheathing, triple-pane windows, and 20-inch, R-60 blown-in cellulose...
Case study describing a DOE Zero Energy Ready Home 2013 Housing Innovation Award Winner in Old Greenwich CT, that scored HERS 42 without PV and HERS 20 with PV.
Case study describing a DOE Zero Energy Ready Home 2013 Housing Innovation Award Winner in Winter Park FL that scored HERS 57 without PV or HERS -7 with PV.
Webinar from Sarah Truitt, Madeline Salzman, Zachary Peterson, and Clint Shireman of NREL, U.S. DOE, and Knauf Insulation on the future of healthy and energy efficient buildings, focusing on workforce training and development. Free EEBA login required.
Fact sheet describing advanced framing techniques that reduce the amount of lumber used in constructing wood-framed houses while providing more space for wall insulation.
Research report anayzing the results of a large retrofit project, turining an old school into near zero energy consumption apartments in Greenfield MA.
Report providing information about improving the energy efficiency and long-term durability of the buildings that are being reconstructed post Katrina in New Orleans.
Research study making several recommendations to whole-home program designers and implementers for improving the cost effectiveness and reach of whole-home programs.
Document serving as a starting point that features initial tools and resources for teams to start collaborating to continually improve the energy efficiency and durability of new houses.
Report exploring feasibility of designing prescriptive retrofit measure packages for typical Chicago region multifamily buildings in order to achieve 25% source energy savings.
Document presenting a simple starting point to determine the most cost-effective Energy Savings Measure Packages (ESMP) for existing homes to achieve 15% and 30% savings in 37 locations across the United States.
Building America Partnership for Improved Residential Construction,
BA-PIRC,
U.S. Department of Energy,
DOE
Publication Date
Description
Research study documenting market-ready energy solutions to improve the efficiency of new affordable housing in the marine climate of Washington State.
Report about development of effective strategies to reduce the overall building energy use in line with Building America goals in this modestly priced market rate project.
Report describing evaluation of several configurations of wall assemblies to determine the accuracy of moisture modeling and make recommendations to ensure durable, efficient assemblies.
Report describing work conducted by the Building Science Corporation (BSC) Building America Research Teams Energy Efficient Housing Research Partnerships project.
Building America Partnership for Improved Residential Construction,
BA-PIRC,
Florida Solar Energy Center,
FSEC,
U.S. Department of Energy,
DOE
Publication Date
Description
Report evaluating the renovation of a 5,800-ft2, multiuse facility located in St. Petersburg, on the west coast of central Florida, in the hot-humid climate.
Report following the evolution of the construction quality process from its development for new homes to its application construction of a HPH with enhanced specifications, and its application in a crawlspace renovation.
Research study determining how well high performance envelope and innovative cooling system interact to cost effectively reduce cooling energy use in this hot-dry climate.