The focus of this brief is on boiler efficiency, sizing requirements, controls, combustion air, and pipe insulation for the 2015 version of the IRC/IECC.
The intent of this brief is to provide code-related information about gas-fired boilers to help ensure that the measure will be accepted as being in compliance with the code. Providing notes for code officials on how to plan reviews and conduct field inspections can help builders or remodelers...
This brief discusses the provisions in the 2015 International Energy Conservation Code (IECC) and International Residential Code (IRC) related to evaporative cooling.
Applicable codes and standards regarding heat pump water heaters (HPWHs) that are an energy-efficient alternative to electric resistance water heaters.
From a model code perspective, submittal of construction documentation, permitting, plan review, and field inspection may be required depending upon the specific details of renovating the floor above an unconditioned space (e.g., floor over a vented crawl space). Several different approaches can be taken to seal and insulate existing floors during a renovation project.
The intent of this brief is to provide code-related information about sealing and insulating existing walls in existing residential buildings to help ensure that the measures will be accepted as being in compliance with the code. Providing notes for code officials on how to conduct plan reviews and field inspections can provide jurisdictional officials with information for acceptance. Providing the same information to builders, contractors, designers, and others is expected to result in increased compliance and fewer innovations being questioned at the time of plan review and/or field inspection.
The intent of this brief is to provide code-related information about sealing and insulating crawl space walls in existing residential buildings to help ensure that the measures will be accepted as being in compliance with the code. Providing the same information to all interested parties (e.g., code officials, builders, contractors, designers, etc.) is expected to result in increased compliance and fewer innovations being questioned at the time of plan review and/or field inspection.
The intent of this brief is to provide code-related information about ductless mini-split heat pumps to help ensure that the measure will be accepted as being in compliance with the code.
Guidance is needed for code-compliant installations of various cladding materials when installed over thicker foam sheathing also known as insulated sheathing or continuous insulation (c.i.).