Air seal and insulate flex ducts
Air seal duct boot to ceiling by installing fiberglass mesh tape and mastic over seam
All other supply ducts and all return ducts in unconditioned space have insulation ≥ R-6
All return air and mechanically supplied outdoor air pass through filter prior to conditioning
An air vent mounted high on the radiator will shut quickly and limit the radiator’s heat output
An air vent mounted low on the radiator will allow more steam to enter the radiator before it shuts
An energy recovery ventilator (ERV) transfers both heat and moisture between incoming and outgoing streams of air
An Energy Recovery Ventilator provides outside air to this dwelling unit; a range hood with dedicated makeup air provides local kitchen exhaust; a Packaged Terminal Heat Pump provides conditioned air and dehumidification is provided separately
An Energy Recovery Ventilator provides outside air to this dwelling unit; a range hood with dedicated makeup air provides local kitchen exhaust; a Packaged Terminal Heat Pump provides conditioned air
An Energy Recovery Ventilator provides outside air to this dwelling unit; a range hood with dedicated makeup air provides local kitchen exhaust; a radiant heating system provides heating
An independent ducted dehumidifier draws air from and supplies air to the living space using its own ducts, not ducts that are connected to the HVAC system
An innovative U-shaped heat pump offers SEER 15 efficiency and operation with smart phones
Anode bars can protect boiler steel without the bad effects of chemical water treatment
At the outlet of the dryer exhaust duct, install a hooded vent with a louvered damper
Back-draft damper still has a piece of tape that prevented it from rattling during shipping
Baffles are installed to protect airflow from the soffits to the ridge vents before the ceiling drywall and attic insulation are installed.
Balanced ventilation dominates ventilation specifications by Zero Energy Ready Home builders
Because flue temperatures are cool, intake and exhaust ducts on a Category 4 direct-vent sealed-combustion condensing furnace can be made of PVC
Bedrooms pressure-balanced and provide 1 sq. in. of free area opening per 1 CFM of supply air or achieve a Rater-measured pressure differential ≤ 3 Pa
Bedrooms pressure-balanced and provide 1 sq. in. of free area opening per 1 CFM of supply air or achieve a Rater-measured pressure differential ≤ 3 Pa
Building cavities not used as supply or return ducts unless they meet Items 3.2, 3.3, 4.1, and 4.2 of this Checklist
By plotting the heating capacities at -4°F and 5°F and drawing a line between them, the capacity at 0°F can be estimated
Cavity used for return is not insulated and is not air sealed, which will pull in air from outside
Central-fan-integrated supply ventilation with exhaust fans for intermittently balanced whole-house ventilation
Clothes dryers vented directly to outdoors, except for ventless dryers equipped with a condensate drain
Collars that are specifically made for flexible duct have a raised bead to prevent the duct from slipping off
Concept behind an evaporative cooler – warm air is cooled as the air passes through a wet medium and gives up some of its heat to evaporate the water
Condensate from this heat pump water heater is routed to a nearby floor drain, shared with the condensate lines from a condensing gas furnace and an air conditioning coil
Connect the plastic application tunnel from the injection equipment to the supply plenum.