Showing results 1 - 5 of 5
Duct/pipe penetration with metal cap flashing and wood blocking for trim attachment
Plan view of duct or pipe penetration through exterior wall showing flashing and air sealing details
Right - The duct shows redundant sealing including the caulk, tape, and flashing
Right - This duct penetration is properly flashed and integrated with the taped, foil-faced foam sheathing layer, which serves as the air and water barrier
Right – The hard metal ducts are located in conditioned space between floor joists and all seams are sealed with approved metal tape.