Showing 1 - 4 of 4 results:
Publication Date
·
Author(s)
Kochkin Vladimir,
Wiehagen Joseph
·
Organization(s)
Home Innovation Research Labs,
HIRL
Description
The Guide addresses walls constructed with 2x4 wood frame studs, wood structural panel (WSP) sheathing as wall bracing and added backing for foam sheathing, a layer of rigid foam sheathing insulation up to 1.5 in. thick over the WSP, and a cladding system installed over the foam sheathing in low...
Publication Date
·
Author(s)
Parlee Mark
·
Organization(s)
Journal of Light Construction
Description
Article describing how omission of two small but critical wall details, a kick-out flashing and a weep screed, lead to extensive water damage to a wall.
Publication Date
·
Author(s)
Lstiburek Joseph W
·
Organization(s)
Building Science Corporation,
BSC
Description
Article describing the evolution of the IRC to permit class 3 vapor retarders (latex paint) in walls coupled with exterior continuous insulation to allow drying and reduce condensation risk.
Publication Date
·
Author(s)
Building Enclosure Moisture Management Institute
·
Organization(s)
BEMMI
Description
A presentation about the need for rainscreens including the damage water and moisture ingress into a home’s siding and framing can cause, and ways to design a resilient wall that drains and ventilates well.