Report describing how changing the air exchange rate of a home (the sum of the infiltration and mechanical ventilation airflow rates) affects the annual thermal conditioning energy.
Webinar from Nick Hurst, Gayathri Vijayakumar, and Karla Butterfield for EEBA on compliance with EPA's Indoor airPLUS program as multifamily buildings reach past five stories high, with special consideration taken for ventilation, air sealing, moisture control, and indoor air quality needs in larger...
Standard covering updates to the expected leakage rates for ductwork constructed to the SMACNA HVAC Duct Construction Standards—Metal & Flexible, duct leakage test procedures; includes recommendations on use of leakage testing, types of test apparatus, and test setup and sample leakage analysis.
Fact sheet describing field validations of a smart ventilation system to assess its effectiveness in assisting low-load homes in humid environments by maintaining acceptable indoor humidity conditions while ensuring adequate ventilation and indoor air quality.
Video discussing how homeowners should return to their homes for the first time after a natural disaster according to the U.S. Department of Housing and Urban Development.
Research study outlining savings from reducing air infiltration, with and without the addition of mechanical ventilation, using two identical laboratory homes designed to model existing Florida building stock.
Report describing a field study of 31 homes to test envelope and duct leakage and fan flowrates, and to determine ventilation operation characteristics.
Technical report describing the research and development of the Ventilation-Integrated Comfort System (VICS) which is a specifically designed, energy-efficient solution that seamlessly integrates with low-capacity, ducted heating, and cooling systems, offering controllable, balanced energy recovery...
Document reviewing four cold-climate northern Illinois energy efficiency retrofit programs to identify practices, tools, and approaches to streamline and reduce costs of comprehensive retrofits, and to improve the consistency of audit and retrofit delivery practices across different programs.
Report about field testing that characterizes the uniformity of room-to-room ventilation air distribution under various operating conditions by examining multi-zone tracer gas decay curves and calculating local age-of-air.
Fact sheet describing a novel, simplified air delivery system using a plug-and-play model that features 3-inch diameter flexible ducts, efficient fittings, and a simplified installation process that resulted in successful market engagement through commercialization.
Paper that illustrates a performance check between the thermal performance of a Massive Insulating Concrete Form (ICF) wall system mocked up and Whole Building Performance criteria such as total space heating and cooling loads (thermal comfort).
Standard establishing a test procedure for evaluating the performance of air-cleaning devices as a function of particle size. This is the current version of the standard, which was published in the year 2017, and is available for preview and purchase at the reference link. The ASHRAE bookstore also...
Standard that describes the minimum requirements for residential buildings to achieve acceptable indoor air quality via dwelling-unit ventilation, local mechanical exhaust, and source control. This version of the standard was published in the year 2022, and is available for preview and purchase at...
Standard that defines the roles of and minimum requirements for mechanical and natural ventilation systems and the building envelope intended to provide acceptable indoor air quality in low-rise residential buildings. This version of the standard was published in the year 2010, and is available for...
Standard that defines the roles of and minimum requirements for mechanical and natural ventilation systems and the building envelope intended to provide acceptable indoor air quality in low-rise residential buildings. This version of the standard was published in the year 2013, and is available for...
Standard that defines the roles of and minimum requirements for mechanical and natural ventilation systems and the building envelope intended to provide acceptable indoor air quality in low-rise residential buildings. This version of the standard was published in the year 2016, and is available for...
Standard that defines the roles of and minimum requirements for mechanical and natural ventilation systems and the building envelope intended to provide acceptable indoor air quality in low-rise residential buildings; published in the year 2019, and is available for preview and purchase at the...
Case study describing how a properly designed duct system is essential for keeping a home comfortable, managing indoor air quality, and maximizing the performance of heating and cooling equipment.
Standard that provides procedures and methods for meeting minimum ventilation and indoor air quality requirements to engineers, design professionals, owners, and jurisdictional authorities where model codes have been adopted. This is the current version of the standard, which was published in the...