Log in or register to create Field Kits and Sales Worksheets. Why register?

Library

This library contains research reports produced by the Building America program and other building science resources used to support this Solution Center. The materials cover both new construction and existing homes. Use the search box and/or the filters to explore hundreds of residential building resources. Access to some references not produced by Building America may require purchase from the publisher. Documents are listed alphabetically. While we continually update our database, links may have changed since posting. Please contact our webmaster if you find broken links.

Author(s): Building Science Corporation
Organization(s): Building Science Corporation
Publication Date: January, 2011

This article addresses the issue of undercutting bedroom doors to provide return airflow from bedrooms resulting in risks such as insufficient airflow, pressure imbalance, energy-inefficient loss of conditioned air, condensation within the wall, and moisture durability issues.

Author(s): Lawrence Berkeley National Laboratory
Organization(s): Lawrence Berkeley National Laboratory
Publication Date: January, 2019
Author(s): Fairey, Parker, Vieira, Martin
Organization(s): FSEC
Publication Date: September, 2014
Preliminary results of two monitored lab homes constructed to represent the thermal characteristics of typical existing Florida homes are presented.
Author(s): Fang, Winkler, Christensen
Organization(s): National Renewable Energy Laboratory
Publication Date: March, 2011

Document presenting analysis results, focusing on relative humidity (RH) excursions, which are defined as unique events of indoor RH above a threshold.

Author(s): Turner, Walker
Organization(s): Lawrence Berkeley National Laboratory

This study uses a computer simulation approach to examine the energy and indoor air quality implications of passive and hybrid ventilation systems.

Author(s): U.S. Environmental Protection Agency
Organization(s): EPA
Publication Date: August, 2009

Report providing information on mechanical, air-cleaning devices for ventilation when conventional methods are not warranted.

Author(s): U.S. Environmental Protection Agency
Organization(s): EPA
Publication Date: December, 2009

Summary of available information and resources on residential air cleaners, including HVAC filters.

Author(s): Aldrich
Organization(s): CARB, Steven Winter Associates, SWA
Publication Date: February, 2014

This document addresses adding—or improving—mechanical ventilation systems to existing homes. The purpose of ventilation is to remove contaminants from homes either directly or by dilution. This report discusses where, when, and how much ventilation is appropriate in a home, including some discussion of relevant codes and...

Author(s): Rudd
Organization(s): Building Science Corporation
Publication Date: February, 2011

Report on whole-house and spot ventilation strategies for improved indoor air quality.

Author(s): Less, Mullen, Singer, Walker
Organization(s): Lawrence Berkeley National Laboratory

This research study used pollutant measurements, home inspections, diagnostic testing and occupant surveys to assess IAQ in 24 new or deeply retrofitted homes designed to be high performance green buildings in California.

Author(s): Martin, Fenaughty, Parker
Organization(s): BA-PIRC, Florida Solar Energy Center, FSEC
Publication Date: January, 2018

Report outlining how Smart ventilation controls (SVC) balance energy consumption, comfort, and IAQ by optimizing mechanical ventilation operation to reduce the heating and/or cooling loads, improve management of indoor moisture, and maintain IAQ equivalence according to ASHRAE 62.2.

Author(s): Singer, Delp, Apte
Organization(s): Lawrence Berkeley National Laboratory
Publication Date: January, 2010

Report on the performance of range hood exhaust fans.

Author(s): Martin, Withers, McIlvaine, Chasar, Beal
Organization(s): BA-PIRC, Florida Solar Energy Center, FSEC
Publication Date: February, 2018

This report evaluates the performance of variable-capacity comfort systems, with a focus on inverter-driven, variable-capacity systems, as well as proposed system enhancements.

Author(s): Turner, Walker
Organization(s): Lawrence Berkeley National Laboratory

This study evaluates the energy, humidity and indoor air quality implications of residential ventilation cooling in all US IECC climate zones.

Author(s): Hodgson, Moyer, Beal
Organization(s): LBNL
Publication Date: September, 2005
A report describing six mechanical ventilation strategies that were evaluated for their ability to control indoor humidity levels over 14-day periods with simulated occupancy.
Author(s): Burdick
Organization(s): IBACOS
Publication Date: December, 2014
Report outlining the issues with using existing ducts with a new low-load HVAC system, which reduces throw at supply registers causing decreased mixing of supply and room air, leading to potential thermal comfort complaints.
Author(s): Building Performance Institute
Organization(s): Building Performance Institute
Publication Date: January, 2016

The following combustion appliance safety inspection must be completed to determine if fossil fuel-fired appliances are operating safely under a depressurized condition.

Author(s): ASHRAE
Organization(s): ASHRAE
Publication Date: January, 2016

ASHRAE Standard 62.1 sets specifications and measures for ventilation system design and indoor air quality.

Author(s): ASHRAE
Organization(s): ASHRAE
Publication Date: January, 2017

Standard establishing a test procedure for evaluating the performance of air-cleaning devices as a function of particle size.

Author(s): ASHRAE
Organization(s): ASHRAE
Publication Date: December, 2013
Standard 55 specifies conditions for acceptable thermal environments and is intended for use in design, operation, and commissioning of buildings and other occupied spaces.
Author(s): ANSI, AHRI
Organization(s): ANSI, AHRI
Publication Date: January, 2015

Standard 680 establishes definitions, classifications, test requirements, data requirements, ratings, operating requirements, marking and nameplate data and conformance conditions for residential air filter equipment.