Log in or register to create Field Kits and Sales Worksheets. Why register?

HVAC - Cooling Equipment


Solution Center Guides


IBACOS investigated the performance of a small-diameter high-velocity heat pump system compared to a conventional system in a new construction triplex townhouse. A ductless heat pump system also was installed for comparison, but the homebuyer backed out because of aesthetic concerns about that system. In total, two buildings, having identical solar orientation and comprised of six townhomes, were monitored for comfort and energy performance.

Guide describing how to install ducted returns in bedroom walls to balance air pressures between rooms and to enable stale air to return to a central heating system's air handler for reconditioning even when room doors are closed.

Guide describing how to upgrade or expand an existing HVAC system.